Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer

Product Details
After-sales Service: Life Long Term Technical Support
Warranty: 1 Year
Display: Digital
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (9)
  • Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
  • Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
  • Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
  • Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
  • Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
  • Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Related Products
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
M510T
Appliance
Food Analysis, Medical Research, Biochemistry, Lab
Portable
Non Portable
Certification
ISO9001
Type
Water Multiparameter Analyzer
Name
Multiparameter Water Quality Analyzer
Parameters
pH/Ec/ISE/Do/Temp.
pH Range
-2.000 to 20.000 pH
pH Accuracy
±0.002 pH
Mv/ORP Range
-2000.00 to 2000.00 Mv
Mv/ORP Accuracy
±0.1 Mv or ±0.03%
Px Range
-2.000 to 20.000 Px
Px Accuracy
±0.002 Px
ISE Range
1e-9 to 9.999e9
ISE Units
Mol/L, Mmol/L, G/L, Mg/L, μg/L
Conductivity Range
0.000 μs/Cm to 3000 Ms/Cm
Resistivity Range
5.00 Ω·cm~100.00 MΩ·cm
TDS Range
0.000mg/L~1000g/L
Salinity Range
(0.00~8.00)%
General Weight
500g (1.1 Lb)
Transport Package
Carton Case
Specification
90× 255× 40 mm
Trademark
Bioda
Origin
China
HS Code
9031809090
Production Capacity
1000 Sets Per Month

Product Description

Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Product Description
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Features
GENERAL FEATURES
² Color High contrast LCD touchscreen, 4.3 inches.
² Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc. 
² Multi-reading feature allows auto-read, timed-read and continuous-read. 
² Automatic/Manual temperature compensation ensures accurate results. 
² Auto-hold feature senses and locks the measurement endpoint.
² Data Storage 1000 sets for each parameter (GLP-compliant).
² Data analysis feature helps user review, compare and recalculate results.
² Support for USB communication.
² Auto-power off feature effectively extends the battery service life.
² Reset feature automatically resumes all settings back to factory default options.
² IP65 waterproof.
 
pH
² 1-8 points calibration with Standard Recognition.
² Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS. 
² User-defined pH buffer or buffer group is supported.
² Automatic electrode diagnosis with pH slope and offset display.
 
Ion
² 1-6 points calibration.
² Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
² Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
² Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
 
Conductivity
² 1-5 points calibration automatically recognizes the standard solutions.
² Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
² Temperature compensation type (none, linear, pure water).
 
DO
² Support for air-saturated water or zero oxygen calibration.
² Auto barometric pressure compensation 
² Manual Salinity Factor Correction
² Selectable pressure unit, including kPa, mbar, Torr, Atm.
Specification
Model
M510T
Parameters
pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)
pH
Range
-2.000 to 20.000 pH
Resolution
0.1, 0.01, 0.001pH
Accuracy
±0.002 pH
Calibration Points
Up to 8
Standard Customization
Yes
Calibration Reminder
Yes
Standard Recognition
USA, NIST, MERK, JIS, GB and DIN buffers
Slope Limit
Yes
mV/ORP
Range
-2000.00 to 2000.00 mV
Resolution
0.1, 0.01 mV
Accuracy
±0.1 mV or ±0.03%
EH ORP Mode
Yes
ORP Calibration Points
1 custom point (relative mV)
pX
Range
-2.000 to 20.000 pX
Resolution
0.1, 0.01, 0.001 pX
Accuracy
±0.002 pX
Calibration Points
Up to 6

ISE
Range
1E-9 to 9.999E9
Units
mol/L, mmol/L, g/L, mg/L, μg/L
Resolution
Up to 4 significant digits
Accuracy
±0.3%
Calibration Points
Up to 8
Conductivity
Range
0.000 μS/cm to 3000 mS/cm
Resolution
0.001 μS/cm minimum,

various with range selection
Accuracy
±0.5% FS
Reference Temperature
5, 10, 15, 18, 20, 25 ºC
Calibration Points
Up to 5
Calibration Reminder
Yes
Standard Recognition
10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm
Resistivity
Range
5.00 Ω·cm~100.00 MΩ·cm
Resolution
0.01 Ω·cm minimum
Accuracy
±0.5% FS
TDS
Range
0.000mg/L~1000g/L
Resolution
0.001mg/L minimum, changed with range
Accuracy
±0.5%
Salinity
Range
(0.00~8.00)%
Resolution
0.01%
Salinity
Accuracy
±0.1%
Dissolved

Oxygen Concentration
Sensor Type
Polarographic
Range
0.00 to 99.99 mg/L
Resolution
0.01mg/L
Accuracy
±0.3mg/L (0.00 to 20.00 mg/L);±10% (20.00 to 99.99 mg/L)
Calibration Reminder
Yes
Calibration Points
Air-saturated water or zero point
Barometric Compensation
Yes
Manual Salinity Factor Correction
Yes
Saturation
Range
(0.0 to 600.0)%
Resolution
0.10%
Accuracy
±10.0%
Temperature
Range
-10 to 135 ºC, 14 to 275 ºF
Unit
ºC, ºF
Resolution
0.1
Relative Accuracy
±0.1
Measurement
Reading Mode
Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts
Reading, Stable, Locked
Temp. Compensation
ATC, MTC
Data management
Data Storage
1000 Groups
Data management
GLP Features
Yes
Inputs
pH Electrode
BNC(Q9)
DO with Temp. Probe
4-pin aviationconnector
Conductivity with Temp. Probe
5-pin aviationconnector
Outputs
USB
USB 2.0 flash memory device, PC, scanner
Bluetooth
printer
Display options
Backlight
Yes
Auto Shutdown
300, 600, 1200, 1800, 3600 sec., off
IP Rating
IP65
Date and Time
Yes
General
Power
Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output
Dimensions
90×255×40 mm
Weight
500g (1.1 lb)
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Related Products
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer


Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Company Profile
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Zhengzhou Bioda Instrument Co., Ltd.
  Zhengzhou Bioda Instrument Co., Ltd. is a professional lab instrument manufacturer located in the central of China. Our company is integrating R&D, production, sales, import and export, and is a leading supplier for one-stop lab equipment. Our products have been exported to all around the world, such as the North America, Australia, South America, South Africa, Europe, Southeast Asia, the Middle East etc, more than 100 countries.
 
  We have professional team to offer pre & after service, can offer quick quotation after discussion and provide online technical support 24h. We always adhere to the core values of integrity, innovation and people-oriented and are committed to providing customers with high-quality products and high-efficiency services.
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Packaging & Shipping
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer
Portable pH Ec Conductivity TDS Do Salinity Ion Ammonia Water 7 in 1 Multi-Parameter Water Quality Analyzer


FAQ

Q1: Are you trading company or manufacturer? 
-We are professional lab products manufacturer with more than 15 years experience.
 
Q2: What's the minimum order quantity?
- 1 set
 
Q3:Can you accept OEM or ODM?
-Yes
 
Q4: How to choose the suitable equipment?
-Please inform us your demands, our technical team will offer best suggestion.
 
Q5:How long is your delivery time?
-Usually 7 days after receiving payment, also depends on order quantity and season.
 
Q6: What is your terms of delivery?
-EXW, FOB, CFR, CIF.DDP, DDU
 
Q7: What is the available payment ways?
-T/T, Western Union, Money Gram , Credit Card, Paypal
 
Q8: How about the warranty?
- One year warranty and lifelong term technical support.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier